WH100 BURNER PLATFORM

suitable for 8, 10, 12 ton/h applications with FGR

suitable for 10, 12, 15 ton/h applications without FGR

The burner platform WH100 has been designed to cover the applications from 8 to 15 ton/h. It is suitable for many applications including, water boilers, steam boiler and oil thermo heaters.

NOx emissions are equivalent to class 3 according EN676, and can be pushed down to <30 mg/m³ to meet the new chinese requirements thanks the use of FGR.

The neat mechanics provide the machine with unparalleled ease of maintenance.

The burner housing has been deeply investigated to develop an efficienct and performing ventilation, in order to guarantee a great stability and powerfull combustion.

The streamlined switch cabinet is compact and graceful, give an easy access to the connection boards and a clean and clear wiring possibility. It is designed to make the operator work in a comfortable position and with plenty of space to manage the wiring.

WH100 BURNER PLATFORM

Categories ,

Description

WH100 Burner platform gives space to three main burner models, which differs for their ventilation and combustion head. The three models aim to cover respectivelly 10, 12, 15 ton/h when working without FGR, and 8, 10, 12 ton/h when working with FGR to achieve 30 mg/m³ of NOx.

The combustion head of these burners has been designed by expert combustion engineers, with their big experience on the field. The combustion head has been newly designed taking into account the best state of the art concepts to guarantee a safe and stable ultra low NOx combustion. It is designed for FGR and Winheight patented.

The digital controller  provides electronic modulation, precise adjustment of servo motor, diagnosis of operation and fault information, mantaining an absolute and high level safety of the combustion process.

Additional information

BRAND

WINHEIGHT

MODEL

WH100.8000GE-LT_FGR
WH100.9500GE-LT_FGR
WH100.12000GE-LT_FGR

COMBUSTION TECHNOLOGY

WINHEIGHT PATENTED "LOTUS" COMBUSTION HEAD FOR FGR

NOx EMISSIONS

<30 mg/m³ @ 3,5% O2 acording chinese regulation with FGR
Class 3 according EN676 without FGR

POWER OUTPUT

1000 – 8000 kW (without FGR)
1180 – 9500 kW (without FGR)
1500 – 12000 kW (without FGR)

MODULATION RATIO

1 : 8 (without FGR)

FUEL

Natural gas, low calorific value 6,99…11,39 kWh/Nm3
On request for other gasses

NOMINAL MOTOR DATA

18,5 kW, 22 kW, 30 kW Three phases
380-400 V / 50 Hz
34,2 A, 37,6 A, 55 A

BURNER COMPOUND CONTROLLER

Full electronic burner controller

FLAME DETECTION

Ionization electrode

MIN GAS WORKING PRESSURE

reccomended minimum 60 mbar
It can differ according combustion chamber pressure and nozzles setting.
Multiple gas train matching according to the inlet gas pressure

Working field